Skip to content

Spec guide

Stacking and load ratings, without the optimism.

Every published box rating is a laboratory number measured on a new, dry, perfectly aligned sample. Your warehouse is none of those things. Here is how to get from one to the other without learning it from a collapsed stack.
Safe default
2 high loaded, 4-wall
Humidity penalty
Up to 50% of strength
Storage penalty
Up to 40% over 90 days

Check a stacking plan

Send the box, the load weight, the stack height and the storage conditions. We will tell you if it is inside the envelope.

A working business address — we reply by email only

US or Canadian number, e.g. (816) 555-0134

Two-letter code or full name, e.g. KS or Kansas

US ZIP (66115 or 66115-1204) or Canadian (M5V 3L9)

Whole number — units, pallets or truckloads

We reply by email — ReGaylord has no telephone line. Your number is only used if a driver needs dock directions. Answered inside one business day.

The answer, first

Take the box compression rating, then multiply it down: ×0.6 for storage beyond thirty days, ×0.5 for high humidity, ×0.8 for used stock in grade 3A, and ×0.7 for any misalignment between stacked boxes. Those multipliers compound. A box rated at 2,400 lb of compression in a laboratory can be carrying a realistic 400 to 600 lb of stack load in a humid warehouse after three months — which is why two high is the sensible default and three high is a decision, not an assumption.

What edge crush actually predicts

Edge Crush Test measures the force a one-inch-wide strip of board withstands on edge before buckling. Multiply that through the McKee relationship — board strength, board thickness and box perimeter — and you get an estimate of box compression strength: the total downward force the empty box resists before it collapses.

Two things follow. First, strength lives in the vertical edges, because the corrugations act as columns; a punctured or crushed corner removes a disproportionate share of the total. Second, a bigger box is not a stronger box — perimeter helps, but height hurts, and a tall box is more vulnerable to the slightest misalignment.

Derating factors to apply to any published compression figure
ConditionMultiplierWhyNotes
Storage 30 – 90 days× 0.65Creep — board deforms slowly under sustained loadBelow 30 days, use × 0.85
Storage beyond 90 days× 0.50Creep continues and accelerates with any humidity cyclingRotate stock instead if possible
Relative humidity 80 – 90%× 0.55Fibre bonds weaken as board takes on waterThe single largest factor in most yards
Relative humidity 65 – 80%× 0.75Measurable loss well before board feels dampMost unconditioned warehouses in summer
Used stock, grade 2A× 0.95Essentially full strength if dry and squareGrade 1A: no derate
Used stock, grade 3A× 0.80Cosmetic wear plus minor edge historyDo not stack 4A loaded at all
Misaligned stacking× 0.70Load must pass corner to corner to workWorst single avoidable error
Pallet overhang× 0.70Bottom edge unsupported, carrying load it was not designed forSee the pallet compatibility guide
Multipliers compound. Apply every condition that is true of your site, not just the worst one.

Worked example

A 5-wall 48 × 40 × 36 box with a laboratory compression figure of 2,400 lb, in grade 2A, stored 60 days in an unconditioned Kansas City warehouse in August, on good pallets, well aligned:

  • 2,400 × 0.65 (storage) = 1,560 lb
  • × 0.55 (humidity) = 858 lb
  • × 0.95 (grade 2A) = 815 lb of realistic stack capacity

If each loaded box weighs 1,600 lb, a second box on top already exceeds that. The stack does not fall over immediately — creep failure is slow and looks like gradual bulging before it looks like a collapse — which is exactly why people believe three high is fine until the day it is not.

Five habits that buy back strength

  1. Align corner to corner. Load travels down the vertical edges. A box set even two inches off centre loses roughly a third of its capacity.
  2. Keep it dry. Roof, dehumidification in summer, and never store on bare concrete without a slip sheet or pallet.
  3. Rotate stock. Creep is cumulative and largely irreversible. First in, first out is a structural policy, not just an inventory one.
  4. Use full pallets. Overhang is the most common cause of bottom-edge crush we see in inbound loads.
  5. Cap the top box. A telescoping cap spreads point loads from whatever inevitably ends up on the top of a stack.
If the bottom course is bulging, the stack is already failing. It has simply not finished yet.
ReGaylord grading standard, note 7

Questions

Stacking, answered.

How high can I stack gaylord boxes?
Two high loaded is the safe default for most 4-wall stock and three high for 5-wall in good condition, stored dry and for less than about thirty days. Those numbers fall quickly with humidity, storage duration, pallet quality and any misalignment between stacked boxes. Always derate rather than test in production.
Why do stacks fail in summer and not in winter?
Humidity. Corrugated at 90 per cent relative humidity retains roughly half the compression strength it has at 50 per cent. A stack that was comfortably inside its rating in a dry February can be over it in a humid July without anything else changing.
Does a used box stack as well as a new one?
In grades 1A to 3A, yes, provided it is dry and the edges are sound. Stacking strength lives in the vertical edges and corner columns. Scuffs, labels and faded print do not touch it. Crushed or rounded bottom edges do, which is why that is an automatic downgrade in our grading.

Reference

Stacking decisions, tabulated.

The same arithmetic as the derating table, run for the combinations we are actually asked about. Find the row closest to your conditions.

Realistic stack capacity for a 5-wall 48 × 40 × 36 with a 2,400 lb laboratory figure
GradeStorageHumidityAlignmentRealistic capacitySafe stack
1AUnder 30 days50%Aligned2,040 lb3 high under 1,000 lb/box
2AUnder 30 days50%Aligned1,938 lb3 high under 950 lb/box
2A60 days65%Aligned1,111 lb2 high under 1,100 lb/box
2A60 days85%Aligned815 lb2 high under 800 lb/box
3A60 days65%Aligned936 lb2 high under 900 lb/box
3A60 days85%Aligned686 lb2 high under 650 lb/box
3A90 days+85%Aligned528 lb1 high, or unloaded only
2A60 days65%Misaligned778 lb2 high under 750 lb/box
2A60 days65%Pallet overhang778 lbFix the pallet before stacking anything
2A60 days85%Misaligned + overhang399 lbDo not stack. Fix both problems.
These are our working numbers, not a standard. They are deliberately conservative because the failure mode is slow, invisible until it is sudden, and expensive.

Reading a stack

Seven warning signs, in the order they appear.

Creep failure is gradual and then sudden. Everything before the last item on this list is a chance to intervene.

  1. 01

    The bottom course looks slightly fuller than the ones above

    Barely perceptible. This is the board starting to deform under sustained load and it is the earliest sign you will get.

  2. 02

    Vertical edges on the bottom box are no longer sharp

    Rounded corners mean the column structure is deforming. At this point the box has permanently lost capacity.

  3. 03

    The stack is no longer plumb

    A lean of an inch or two across three boxes. Usually blamed on the pallet, usually the board.

  4. 04

    Visible bulging on one face

    The face that is bulging is carrying more than its share, which means the load was never centred.

  5. 05

    Creaking during handling

    Board does not creak when it is within its envelope. Anybody who has worked a floor knows this sound.

  6. 06

    Flaps no longer sit flat

    The top of the box has deformed enough that the closure has changed shape. Late-stage.

  7. 07

    It is on the floor

    There is no warning sign after this one.

Practice

Ten habits that buy capacity back for free.

  • Align corner to corner — worth roughly 30%
  • Keep storage dry — worth up to 45%
  • Rotate stock first-in, first-out
  • Match the pallet; measure it, do not trust the label
  • Seven or more top deck boards above 1,500 lb
  • Cap the bottom box to spread point loads
  • Centre the load inside the box, not just the box on the pallet
  • Keep stacks eighteen inches off exterior walls
  • Never stack a 4A box loaded
  • Derate in summer using the honest humidity figure, not the specification

Send us your stacking plan before you build it.

Box, load weight, height, storage time and conditions. We will tell you honestly whether it holds.

Get a quote